Air disinfection machine wall-mounted installation requirements and installation steps
by:Funglan
2021-02-23
Air disinfection machine wall-mounted installation requirements and steps A. Installation requirements: The height of the mounting plate is 2m from the ground, and the hanging plate is fixed with 4 random plastic expansion screws; plastic expansion screw specification is M10ⅹ60mm; plastic expansion screw is inserted into the hanging plate The hanging plate should be fixedly installed on the plastic expansion pegs and should not be loosened; Make sure the machine hanging plate is parallel to the wall; the height of the machine is 3 meters high as an example, and installed at a 2 meters high position. Reserve a 220v electrical socket in advance, the machine power outlet is on the right side of the fuselage, and the power cord is about 1.8 meters long. B. Installation steps: Use an impact drill to install the disinfection machine and drill 4 installation holes with a diameter of 10mm perpendicular to the wall; insert M10ⅹ60mm plastic expansion screw and use a tool to tighten the other screw; put the metal hanging plate parallel to the ground. Tighten the second screw; then drill 2 10mm mounting holes to fasten the hanging plate; hang the machine; insert the power plug into a power supply socket that meets the power requirements; manually select various functions to confirm that the machine is working properly.