Ultraviolet air disinfection machine-multifunctional air disinfection machine operation and setting

by:Funglan     2021-02-26
Ultraviolet air disinfection machine-multifunctional air disinfection machine operation and setting of ultraviolet air sterilizer-multifunctional medical ultraviolet air disinfection machine, adopting diversified disinfection and sterilization technology, is very effective in preventing bacteria from developing resistance and killing microorganisms in the hospital air It is fast, efficient, and has no dead ends, which can effectively block the spread of the virus in the hospital air. Ultraviolet air disinfection machine-multifunctional medical ultraviolet air disinfection machine functions: filter and purify the air, sterilize and disinfect, remove all kinds of odors in the air, and remove harmful gases in the air. Here is an introduction to the operation and settings of the UV air disinfection machine-multifunctional medical UV air disinfection machine. 1. Ultraviolet air disinfection machine-automatic disinfection mode of multifunctional medical ultraviolet air disinfection machine: 1) Press the automatic operation key to select the automatic operation mode. 2) In the automatic operation mode, press the setting key, the increment key and the decrement key to adjust the automatic switch-on time. The adjustment sequence is: 1ON, 1OFF --- 6ON, 6OFF. 3) After the machine selects the automatic operation mode, it will automatically turn on and off according to the set time. During the startup time, the fan and the sterilization factor work; during the shutdown time (this time period is also called the standby state), the fan and the sterilization factor are turned off. 4) The swing wind can be selected by pressing the swing wind key to swing and stop swinging. 5) After adjusting the power on and off time, you can press it to exit in a cycle, or you can press the power button in the middle to exit or unplug the power directly to exit. 6) After adjusting the switch time, the last time setting value will be automatically saved and saved forever. 2. Ultraviolet air disinfection machine-multifunctional medical ultraviolet air disinfection machine manual disinfection mode: 1) Press the temporary operation button, select temporary disinfection, disinfect according to the set time, and automatically return to automatic operation mode when the disinfection time is up. 2) The disinfection time adopts countdown mode, and the countdown time can be set freely. 3) In the temporary operation mode, press the setting key, the increment key and the decrement key to adjust the disinfection time, and the maximum can be set to 24 hours. 4) During temporary disinfection, the fan and sterilization factor work, and the swing wind can be selected to swing and stop swinging by pressing the swing wind button. 5). After adjusting the disinfection time, you can press the cycle to the end to exit, you can also press the power button in the middle to exit or unplug the power directly to exit. 6) After adjusting the switch time, the last time setting value will be automatically saved and saved forever. 3. In the power-on state, you can press the swing button to pause the swing, and press the swing button again to continue the swing. 4. When the UV air disinfection machine-multifunctional medical UV air disinfection machine is turned on or in standby mode, short press the wind speed key to select the predetermined running wind speed. 5. Long press the wind speed key for 3 seconds. You can query the remaining working time of the fan (filter). In the query state, you can press the up and down keys to adjust the cycle time. When the fan is working, it counts down the fan (filter) time, when it is reduced to 0, it will prompt:! Please clean or replace the filter. Long press the wind speed key again to set. The maximum working time of the fan can be set to 99999 hours. 6. Long press the temporary operation key for 3 seconds to query the remaining working time of the sterilization factor. In the query state, you can press the up and down keys to adjust the cycle time. When the bactericidal factor is working, it counts down the time. When it is reduced to 0, it prompts:! Please replace the disinfection factor. If the sterilization factor cycle time is set to 0, the prompt function can be shielded and no prompt will appear. If the sterilization factor is running down to 0 and a prompt appears, press the sterilization key again to set it. The maximum cycle working time of the sterilization factor can be set to 99999 hours. 7. Long press to automatically run the key for 3 seconds, and the working time of the fan (filter) and sterilization factor can be restored to the factory default value. 8. Long press the setting button for 3 seconds to enter the current state of Beijing time adjustment, press the up and down keys to adjust the corresponding time value. 9. Press the power button to select the UV air disinfection machine-multifunctional medical UV air disinfection machine on/off status. When the machine is turned off, the LCD and backlight are turned off. Pressing other keys is invalid. If the sterilizer is not used for a long time, it is recommended to turn off the power switch.
air sterilizer are all following the most compatible manufacturing regulations.
The best for custom air cleaners is one that works best for your needs and what you can support in your home. Among Qingdao Funglan Environmental Protection & Technology Co., Ltd.'s diversified list of products at different price ranges, you will surely find your one with high quality. make your choice at Funglan Air Purifier!
The global market is estimated to reach a value of almost custom air cleaners in the next decade. have a robust position in the custom air cleaners market because of its proven high potency in custom air cleaners.
Custom message
Chat Online 编辑模式下无法使用
Chat Online inputting...
Thank you for your enquiry, we will get back to you ASAP