Use method and operation process of ozone disinfection machine in bed unit

by:Funglan     2021-04-02
Bed unit ozone disinfection machine use method   1, operation method   ①Use the disinfection bag   a) Use the disinfection bag: take out the disinfection bag and open it, lay it flat on the bed to be disinfected, and tuck the surrounding area under the mattress.   Note: Visually check whether the disinfection bag has holes and air holes. If it is damaged, it cannot be used. Please change to a new disinfection bag before use.  B) Use of the disinfection bag: Put the sheets, mattresses, quilts and other items to be disinfected into the disinfection bag, and tie the entrance well.   Note: Put the air nozzle on the disinfection bag upwards to facilitate operation, and make sure that the disinfection bag has been tied up and there is no leakage.  ②Air pipe installation   Push the bed unit sterilizer to a suitable position beside the bed, remove the air pipe of the sterilizer from the machine, and open the air nozzle of the disinfection bag, and then insert the head of the air pipe into the opened air nozzle.   Note: Confirm that the trachea and the gas nozzle are inserted correctly.  ③Power cord   Take out the power cord from the accessory bag, plug it into the power socket under the back of the machine, and plug the other end of the power cord into a nearby power socket.  ④Disinfection method:   When performing disinfection, the time can be adjusted according to the amount of disinfection objects put in the disinfection bag. It is better to fully bulge the disinfection bag. The disinfection time is more than 30 minutes, and the time setting is determined. Press the on/off key, the display will light up, press the 'disinfection' button, and the disinfection machine will start to work. After disinfection, the ozone generator will stop working. After sealing for 30 minutes, the disinfection bag can be removed.  2. Introduction to the disinfection machine panel and function setting  ①Press the 'timing' key to set the timing shutdown time for disinfection or vacuuming. On the remote control, you can use the 'increase' and 'decrease' keys to adjust from 0 to 240 minutes. On the machine panel, you can use the '▲' key to adjust the time. After setting, press the 'timing' key to confirm.  ②Press the 'disinfection' button, the disinfection indicator will light up, and the disinfection will start. The disinfection period lasts for 30 minutes.  ③Press the 'Evacuation' button to perform the vacuuming function. The vacuuming time is 10 minutes.  3. How to use the remote control:   ①Aim the remote control at the receiving window of the machine, press the 'on/off' button on the remote control, and the display window will display Beijing time. When the bed unit disinfection machine uses the 'clock' button on the remote control to calibrate Beijing time, press the 'clock' button, the numbers on the display window start to flash, adjust the required numbers through the 'increase' and 'decrease' keys, and then press the 'clock' button again. 'Clock' button to set the second digit, press the 'Clock' button in turn to set the third and fourth digits, and then press the 'Clock' button to confirm Beijing time after setting. To use the 'program-controlled timing' button on the remote control, press the 'program-controlled timing' button, the first indicator next to the display window will light up, and then press the 'timing' button again, the first digit on the display window will flash, and you will pass 'Increase' and 'Decrease' keys to adjust the required number, and then press the 'Timing' key. The second digit flashes. At this time, use the 'Increase' and 'Decrease' keys to adjust the second digit, and so on to proceed to the third digit. , The fourth digit is set.   After the setting is completed, press the 'timing' button to confirm. This process is the automatic start time of the 'program-controlled timer' for the first time period. To set the power-on time, you must set the power-off time. Otherwise, the machine will be turned on for a long time and cannot be stopped.   If you want to set the shutdown time, you need to press the 'Program Control Timer' button. The first indicator light next to the display window will flash, and then press the 'timing' button as described above to set the first period of automatic shutdown time. After the setting is completed, press the 'program-controlled timing' button to set the second, third, fourth, fifth, and sixth time periods. If you don't need to set it again, press the 'timing' button to confirm, then press the 'clock' button return. At this time, the machine will automatically turn on and off according to the time period you currently set. This machine can set 6 time periods according to user needs. When setting the second time period to turn on or off time, as described above, the second indicator light will light up or flash, and so on, 6 time periods can be set.  ②Press the 'disinfection' button on the remote control, the disinfection indicator will light up, and the disinfection will start. The disinfection time is 30 minutes.  ③Press the 'Purge' button on the remote control to perform the vacuuming function. The vacuuming time is 10 minutes.  ④ Press the 'accumulated timer' button on the remote control, and the cumulative working time of the machine will be displayed.  Bed unit ozone disinfection machine installation and operation process   1. After unpacking, first take out the accessory bag from the packing box.   2. Take out the disinfection air tube from the accessory bag, and insert the soft end into the air outlet on the upper end of the back of the disinfection machine with water. The installation work is now complete. Precautions for the use of bed unit disinfection machine 1. Before using this machine, please read the instruction manual carefully;    2. The use of this machine must be operated in accordance with the rules specified in the manual;    3. It is prohibited to use in flammable and explosive places;    4. When using, Pay attention to opening the doors and windows;   5, the transformer of the machine has high voltage, and the power supply must be cut off during installation and maintenance;   6, the air inlet and outlet of the machine are strictly prohibited to be covered or obstructed;   7, do not insert anything into the machine from the gap Inside, otherwise it will cause a fire or electric shock, do not spill any liquid on the disinfection machine;  
Custom message
Chat Online 编辑模式下无法使用
Chat Online inputting...
Thank you for your enquiry, we will get back to you ASAP